Technical Specifications

OPzS2-1750 Detailed Parameters

ModelOPzS2-1750
TehnologieTubular Flooded Lead-Acid Battery
Tensiune nominală2V
Capacitate nominală1750Ah
Dimensiuni399 × 212 × 771 mm
Length399 mm
Width212 mm
Height771 mm
Înălțime totală826 mm
Greutate uscată105.0 kg
Greutate umedă140.2 kg
Greutate acid35.2 kg
TerminalM8 screw hole / model dependent
Design Life20+ years float service
Tensiune float2.23V/cell @25°C
Tensiune de egalizare2.35V/cell @25°C
Charge Current Limit0.10C10A
Aplicații

Aplicații recomandate

  • Utility substation
  • Telecom central office
  • Stocare solară
  • UPS
Dimensiuni, total height, weight and terminal data are critical for replacement matching, cabinet design and freight calculation.
Product Features

Key Features & Advantages

Not only basic specifications: this section explains why buyers choose this product.

Tubular flooded designRobust positive tubular plates for industrial stationary systems.
Easy maintenanceTransparent flooded container supports inspection.
High backup reliabilitySuitable for utility and telecom central office.
Excellent recoveryStrong discharge capability.
Engineering installationIdeal for rack-based battery rooms.
Long service lifeDesigned for demanding float service.
Engineering Data

Technical Performance Reference

Reference charts help buyers evaluate charging behavior, temperature influence and cycle expectations.

Caracteristici de încărcare

Reference Curve

Final voltage settings should follow datasheet and project conditions.

Temperature Performance

Reference Curve

Capacitate and charging voltage are affected by ambient temperature.

Cycle Life Reference

Reference Curve

Cycle life depends on depth of discharge, temperature and charging method.

Why are dimensions and weight important?

They help confirm cabinet compatibility, rack layout, freight cost and replacement fit.

How can I get the official datasheet?

Contact sales@chisen.cn or WhatsApp +86 131 6622 6999.

Product Images

OPzS2-1750 2V 1750Ah Tubular Flooded Battery Gallery

V25 product image gallery mounted from the current website asset library.

WhatsApp
Inginerie inteligență V26

OPzS Tubular Flooded Engineering Data

OPzS2-1750 2V 1750Ah Tubular Flooded Battery is structured as an engineering-grade product page for international B2B buyers, combining technical specifications, application logic, performance curves, Întrebări frecvente and datasheet access.

Poziționare inginerească

OPZS2-1750 belongs to the CHISEN Tubular flooded stationary battery platform. This page is designed for selection, comparison and inquiry by distributors, OEM buyers, system integrators and project engineers.

TehnologieTubular flooded
Tensiune2V cells
AplicațieStationary power
ÎntreținereElectrolyte inspection
Design FocusLong service life
Project LevelIndustrial / utility

Aplicații recomandate

Aplicație mapping helps buyers select the correct battery platform by industry and working condition rather than by model number only.

Utility backupTelecom powerIndustrial DC systemsStocare solarăPower plantsSubstations

Curbe de performanță inginerești

The following curve area standardizes how charging, discharging and storage behavior are explained across CHISEN product pages. Final curve values should be confirmed by the model-specific datasheet when available.

Caracteristici de încărcare

Shows typical charging voltage, charging current and capacity recovery behavior.

Caracteristici descărcare

Helps engineers estimate voltage behavior under different discharge rates.

Auto-descărcare / temperatură

Supports storage planning and high-temperature market evaluation.

Întrebări frecvente inginerie

What is OPzS battery?

OPzS is a flooded tubular stationary battery for industrial and utility backup power applications.

OPzS vs OPzV: which should I choose?

Choose OPzS where flooded battery maintenance is acceptable; choose OPzV where sealed low-maintenance gel technology is preferred.

What applications use OPzS?

OPzS is used in substations, telecom, utility backup, solar storage and industrial DC power systems.

Încredere industrială & suport OEM

  • OEM / ODM branding, label, carton and export packing support.
  • Model-based inquiry handling for distributors and project buyers.
  • Suitable for multi-language product pages with one shared global asset library.
  • Structured content supports SEO, GEO, AEO and AI citation systems.
OEMEtichetă & ambalare
B2BAprovizionare vrac
ExportPiețe globale
AI-readyDate structurate