OPzS2-3000 2V 3000Ah Tubular Flooded Battery

OPzS2-3000 2V 3000Ah tubular flooded stationary battery for utility, telecom and industrial backup systems.

576 × 212 × 771 mm242.0 kgAngebot erhalten
CHISEN OPzS2-3000 2V 3000Ah Tubular Flooded Battery product image
Schnellanfrage

Request Price & Datasheet

E-Mail: sales@chisen.cn

Alternative E-Mail: chisenbattery@gmail.com

WhatsApp: +86 131 6622 6999

Webseite: www.chisenenergy.com

Send model OPzS2-3000, quantity, application and destination country.

Jetzt WhatsApp-Vertrieb
Technical Specifications

OPzS2-3000 Detailed Parameters

ModellOPzS2-3000
TechnologieTubular Flooded Lead-Acid Battery
Nennspannung2V
Nennkapazität3000Ah
Abmessungen576 × 212 × 771 mm
Length576 mm
Width212 mm
Height771 mm
Gesamthöhe826 mm
Trockengewicht179.0 kg
Nassgewicht242.0 kg
Säuregewicht63.0 kg
TerminalM8 screw hole / model dependent
Design Life20+ years float service
Erhaltungsladespannung2.23V/cell @25°C
Ausgleichsspannung2.35V/cell @25°C
Charge Current Limit0.10C10A
Anwendungen

Empfohlene Anwendungen

  • Utility substation
  • Telecom central office
  • Solarstromspeicher
  • UPS
Abmessungen, total height, weight and terminal data are critical for replacement matching, cabinet design and freight calculation.
Product Features

Key Features & Advantages

Not only basic specifications: this section explains why buyers choose this product.

Tubular flooded designRobust positive tubular plates for industrial stationary systems.
Easy maintenanceTransparent flooded container supports inspection.
High backup reliabilitySuitable for utility and telecom central office.
Excellent recoveryStrong discharge capability.
Engineering installationIdeal for rack-based battery rooms.
Long service lifeDesigned for demanding float service.
Engineering Data

Technical Performance Reference

Reference charts help buyers evaluate charging behavior, temperature influence and cycle expectations.

Ladeeigenschaften

Reference Curve

Final voltage settings should follow datasheet and project conditions.

Temperature Performance

Reference Curve

Kapazität and charging voltage are affected by ambient temperature.

Cycle Life Reference

Reference Curve

Cycle life depends on depth of discharge, temperature and charging method.

Why are dimensions and weight important?

They help confirm cabinet compatibility, rack layout, freight cost and replacement fit.

How can I get the official datasheet?

Kontakt sales@chisen.cn or WhatsApp +86 131 6622 6999.

Product Images

OPzS2-3000 2V 3000Ah Tubular Flooded Battery Gallery

Multiple product views are shown when exact model images are available in the CHISEN local asset library.

WhatsApp
V26 Engineering-Intelligenz

OPzS Tubular Flooded Engineering Data

OPzS2-3000 2V 3000Ah Tubular Flooded Battery is structured as an engineering-grade product page for international B2B buyers, combining technical specifications, application logic, performance curves, FAQ and datasheet access.

Technische Positionierung

OPZS2-3000 belongs to the CHISEN Tubular flooded stationary battery platform. This page is designed for selection, comparison and inquiry by distributors, OEM buyers, system integrators and project engineers.

TechnologieTubular flooded
Spannung2V cells
AnwendungStationary power
WartungElectrolyte inspection
Design FocusLong service life
Project LevelIndustrial / utility

Empfohlene Anwendungen

Anwendung mapping helps buyers select the correct battery platform by industry and working condition rather than by model number only.

Utility backupTelecom powerIndustrial DC systemsSolarstromspeicherPower plantsSubstations

Technische Leistungskurven

The following curve area standardizes how charging, discharging and storage behavior are explained across CHISEN product pages. Final curve values should be confirmed by the model-specific datasheet when available.

Ladeeigenschaften

Shows typical charging voltage, charging current and capacity recovery behavior.

Entladeeigenschaften

Helps engineers estimate voltage behavior under different discharge rates.

Selbstentladung / Temperatur

Supports storage planning and high-temperature market evaluation.

Engineering-FAQ

What is OPzS battery?

OPzS is a flooded tubular stationary battery for industrial and utility backup power applications.

OPzS vs OPzV: which should I choose?

Choose OPzS where flooded battery maintenance is acceptable; choose OPzV where sealed low-maintenance gel technology is preferred.

What applications use OPzS?

OPzS is used in substations, telecom, utility backup, solar storage and industrial DC power systems.

Industrielles Vertrauen und OEM-Support

  • OEM / ODM branding, label, carton and export packing support.
  • Modell-based inquiry handling for distributors and project buyers.
  • Suitable for multi-language product pages with one shared global asset library.
  • Structured content supports SEO, GEO, AEO and AI citation systems.
OEMEtikett und Verpackung
B2BGroßlieferung
ExportGlobale Märkte
KI-bereitStrukturierte Daten